Standard detectors for neutron diffraction experiments are typically 3He filled proportional counters. Indeed, in the near future the 3He availability will be greatly reduced, so the R&D activity on alternative neutron counters is a very important issue to be addressed. Scintillator detectors could be considered as one of these alternatives. In this context, a prototype thermal neutron counter composed of a yttrium–aluminium–perovskite scintillator crystal coupled to a silicon photomultiplier (SiPM) and a standard photomultiplier tube (PMT) was used in time of flight neutron diffraction experiments on the INES spectrometer at the ISIS spallation neutron source. Neutron detection was realized by attaching the crystal to a natural cadmium sheet,used as a (n,γ) converter. Results show that the SiPM-based readout detection system has promising performances with respect to that based on a standard PMT. Diffraction patterns recorded with the 3He tubes’ neutron counters in use on INES allowed a comparative assessment of the SiPM-based device for time of flight neutron diffraction experiments, with respect to the standard detection technique.

A gamma-ray detector with silicon photomultiplier (SiPM) readout for neutron diffraction experiments at spallation neutron sources

Festa G;
2010-01-01

Abstract

Standard detectors for neutron diffraction experiments are typically 3He filled proportional counters. Indeed, in the near future the 3He availability will be greatly reduced, so the R&D activity on alternative neutron counters is a very important issue to be addressed. Scintillator detectors could be considered as one of these alternatives. In this context, a prototype thermal neutron counter composed of a yttrium–aluminium–perovskite scintillator crystal coupled to a silicon photomultiplier (SiPM) and a standard photomultiplier tube (PMT) was used in time of flight neutron diffraction experiments on the INES spectrometer at the ISIS spallation neutron source. Neutron detection was realized by attaching the crystal to a natural cadmium sheet,used as a (n,γ) converter. Results show that the SiPM-based readout detection system has promising performances with respect to that based on a standard PMT. Diffraction patterns recorded with the 3He tubes’ neutron counters in use on INES allowed a comparative assessment of the SiPM-based device for time of flight neutron diffraction experiments, with respect to the standard detection technique.
File in questo prodotto:
File Dimensione Formato  
mst10_3_035901[1].pdf

non disponibili

Dimensione 668 kB
Formato Adobe PDF
668 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14249/1035
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact