The dual-radiator RICH detector of the ePIC experiment at the future Electron-Ion Collider will make use of SiPM sensors for the detection of Cherenkov light. The photodetector will cover approximate to 3 m2 with 3 x 3 mm2 pixels, for a total of more than 300k readout channels and will be the first application of SiPMs for single-photon detection in a HEP experiment. SiPMs are chosen for their low cost and high efficiency in magnetic fields (approximate to 1 T at the dRICH location). However, since they are not radiation hard, careful testing and attention are required to preserve single-photon counting capabilities and maintain dark count rates (DCR) under control over the years of running of the ePIC experiment. We present an overview of the ePIC-dRICH detector system and the current status of the R&D performed for the operation of the SiPM optical readout subsystem. Special attention will be paid to the recent results of the beam test of a prototype SiPM readout plane with a large area consisting of a total of up to 2048 3 x 3 mm2 sensors. The prototype photodetector is modular and based on a new EIC-driven photodetection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and Time to Digital Converter (TDC) electronics in a volume of approximate to 5 x 5 x 14 cm3. Several PDU modules were built and successfully tested with particle beams at CERN-PS in October 2023 and May 2024. The data were collected with a complete chain of front-end and readout electronics based on the ALCOR chip, developed by INFN Torino.

The SiPM readout plane for the ePIC-dRICH detector at the EIC: Overview and beam test results

Garbini, M.;
2025-01-01

Abstract

The dual-radiator RICH detector of the ePIC experiment at the future Electron-Ion Collider will make use of SiPM sensors for the detection of Cherenkov light. The photodetector will cover approximate to 3 m2 with 3 x 3 mm2 pixels, for a total of more than 300k readout channels and will be the first application of SiPMs for single-photon detection in a HEP experiment. SiPMs are chosen for their low cost and high efficiency in magnetic fields (approximate to 1 T at the dRICH location). However, since they are not radiation hard, careful testing and attention are required to preserve single-photon counting capabilities and maintain dark count rates (DCR) under control over the years of running of the ePIC experiment. We present an overview of the ePIC-dRICH detector system and the current status of the R&D performed for the operation of the SiPM optical readout subsystem. Special attention will be paid to the recent results of the beam test of a prototype SiPM readout plane with a large area consisting of a total of up to 2048 3 x 3 mm2 sensors. The prototype photodetector is modular and based on a new EIC-driven photodetection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and Time to Digital Converter (TDC) electronics in a volume of approximate to 5 x 5 x 14 cm3. Several PDU modules were built and successfully tested with particle beams at CERN-PS in October 2023 and May 2024. The data were collected with a complete chain of front-end and readout electronics based on the ALCOR chip, developed by INFN Torino.
2025
SiPM EIC dRICH Test beam ePIC Cherenkov T10 CERN PID
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14249/1670
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact