Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and C-12 ions are already used for irradiation in clinical routine, while new ions like He-4 and O-16 are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak - BP), during the treatment. To ensure correct 'in-treatment' dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an O-16 beam during target irradiation can be considered as candidates for O-16 beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an O-16 beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90 degrees and 60 degrees with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.

Secondary radiation measurements for particle therapy applications: Charged secondaries produced by O-16 ion beams in a PMMA target at large angles

Marafini M;
2019-01-01

Abstract

Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and C-12 ions are already used for irradiation in clinical routine, while new ions like He-4 and O-16 are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak - BP), during the treatment. To ensure correct 'in-treatment' dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an O-16 beam during target irradiation can be considered as candidates for O-16 beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an O-16 beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90 degrees and 60 degrees with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14249/327
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact