Purpose: Beta-particle radioguided tumor resection may potentially overcome the limitations of conventional gamma-ray guided surgery by eliminating, or at least minimizing, the confounding effect of counts contributed by activity in adjacent normal tissues. The current study evaluates the clinical feasibility of this approach for a variety of radionuclides. Nowadays, the only beta(-) radioisotope suited to radioguided surgery is Y-90. Here, we study the beta(-) probe prototype capability to different radionuclides chosen among those used in nuclear medicine. Methods: The counting efficiency of our probe prototype was evaluated for sources of electrons and photons of different energies. Such measurements were used to benchmark the Monte Carlo (MC) simulation of the probe behavior, especially the parameters related to the simulation of the optical photon propagation in the scintillation crystal. Then, the MC simulation was used to derive the signal and the background we would measure from a small tumor embedded in the patient body if one of the selected radionuclides is used. Results: Based on the criterion of detectability of a 0.1 ml tumor for a counting interval of 1 s and an administered activity of 3 MBq/kg, the current probe yields a detectable signal over a wide range of Standard Uptake Values (SUVs) and tumor-to-non-tumor activity-concentration ratios (TNRs) for Si-31, P-32, Zr-97, and Re-188. Although efficient counting of Br-83, I-133, and Sm-153 proved somewhat more problematic, the foregoing criterion can be satisfied for these isotopes as well for sufficiently high SUVs and TNRs.

Feasibility of beta-particle radioguided surgery for a variety of "nuclear medicine" radionuclides

Marafini M;
2017-01-01

Abstract

Purpose: Beta-particle radioguided tumor resection may potentially overcome the limitations of conventional gamma-ray guided surgery by eliminating, or at least minimizing, the confounding effect of counts contributed by activity in adjacent normal tissues. The current study evaluates the clinical feasibility of this approach for a variety of radionuclides. Nowadays, the only beta(-) radioisotope suited to radioguided surgery is Y-90. Here, we study the beta(-) probe prototype capability to different radionuclides chosen among those used in nuclear medicine. Methods: The counting efficiency of our probe prototype was evaluated for sources of electrons and photons of different energies. Such measurements were used to benchmark the Monte Carlo (MC) simulation of the probe behavior, especially the parameters related to the simulation of the optical photon propagation in the scintillation crystal. Then, the MC simulation was used to derive the signal and the background we would measure from a small tumor embedded in the patient body if one of the selected radionuclides is used. Results: Based on the criterion of detectability of a 0.1 ml tumor for a counting interval of 1 s and an administered activity of 3 MBq/kg, the current probe yields a detectable signal over a wide range of Standard Uptake Values (SUVs) and tumor-to-non-tumor activity-concentration ratios (TNRs) for Si-31, P-32, Zr-97, and Re-188. Although efficient counting of Br-83, I-133, and Sm-153 proved somewhat more problematic, the foregoing criterion can be satisfied for these isotopes as well for sufficiently high SUVs and TNRs.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14249/339
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact